Table 2 Comparison of methods ro isolate DNA from whole blood sample

From: Isolation of DNA from Arthrospira platensis and whole blood using magnetic nanoparticles (Fe3O4@OA and Fe3O4@OA@SiO2)

 

Method

Phenol/Chloroform

Fe3O4@OA

Fe3O4@OA@SiO2

Silica column

DNA yield (µg)

10.32 ± 5.80

2.3 ± 0.13

3.7 ± 0.77

0.36 ± 0.05

A260/A280

2.05 ± 0.09

1.13 ± 0.06

1.05 ± 0.01