Skip to main content

Table 1 Intra-/inter-day accuracy and precision of alpelisib in mouse and human plasma

From: Bioanalysis of alpelisib using liquid chromatography–tandem mass spectrometry and application to pharmacokinetic study

 

Nominal concentration (ng/mL)

LLOQ

LQC

MQC

HQC

1

3

150

1600

(A) Mouse plasma

Intra-day (n = 6)

  Measured concentration (ng/mL; mean ± SD)

1.00 ± 0.03

3.05 ± 0.27

149 ± 6

1530 ± 70

  Accuracy (RE, %)

0.000

1.61

− 0.667

− 4.17

  Precision (RSD, %)

3.23

8.85

4.29

4.42

Inter-day (n = 18)

  Measured concentration (ng/mL; mean ± SD)

0.998 ± 0.030

2.97 ± 0.19

145 ± 9

1570 ± 60

  Accuracy (RE, %)

− 0.189

− 1.11

− 3.26

− 1.98

  Precision (RSD, %)

3.02

6.37

6.15

3.80

(B) Human plasma

Intra-day (n = 6)

  Measured concentration (ng/mL; mean ± SD)

0.998 ± 0.010

3.08 ± 0.09

154 ± 1

1550 ± 10

  Accuracy (RE, %)

− 1.13

2.56

2.33

− 3.13

  Precision (RSD, %)

0.961

2.97

0.798

0.816

Inter-day (n = 18)

  Measured concentration (ng/mL; mean ± SD)

0.977 ± 0.019

3.03 ± 0.12

153 ± 6

1610 ± 70

  Accuracy (RE, %)

− 2.29

0.963

2.30

0.451

  Precision (RSD, %)

1.98

3.83

3.76

4.09

  1. RE, Relative error, calculated as (calculated concentration − theoretical concentration)/theoretical concentration × 100%; RSD, relative standard deviation, calculated as standard deviation of concentration/mean concentration × 100%; and SD, standard deviation