Skip to main content

Table 3 Extraction performance of the two Mag-CNTs/d-µSPE methods and the SPE methods

From: Performance comparison between solid phase extraction and magnetic carbon nanotubes facilitated dispersive-micro solid phase extractions (Mag-CNTs/d-µSPE) of a cyanide metabolite in biological samples using GC–MS

 

Mag-CNTs-COOH/d-µSPE (multi-stepped)a

 

Mag-CNTs-COOH/d-µSPE (one-step)

 

Mag-CNTs-SO3H/d-µSPE

 

SPE

Performance

Synthetic urine

Bovine blood

Synthetic urine

Bovine blood

Synthetic urine

Bovine blood

Bovine blood

LOD (ng/mL)

15

25

5

10

5

10

1

LOQ (ng/mL)

30

30

10

60

10

60

25

Level of Calibrators

7

6

7

6

7

6

7

Regression Model

Non-weighted linear

Non-weighted linear

Non-weighted linear

Non-weighted linear

Quadratic

Quadratic

Non-weighted linear

R2 value

0.9985

0.9919

0.9982

0.9983

0.9982

0.9982

0.9980

Linear range

30–1000

30–1000

10–1000

60–1000

10–1000

60–1000

25–1000

  1. aData was obtained from Li et al. (2019a)