Table 2 Absolute and IS normalized matrix effect of lenalidomide in human plasma

From: Development and validation of a liquid chromatography-tandem mass spectrometric method for the determination of lenalidomide in human plasma and its application on bioequivalence studies

Spiked conc. (ng/mL)Absolute matrix factorIS normalized matrix factor
26.250.970.89
807.641.020.91