Skip to main content

Table 3 Accuracy of the method ( n= 3)

From: Stability-indicating RP-HPLC method for the determination of 6-gingerol in polyherbal formulations

% of standard spiked to the sample

Theoretical content (μg/mL)

Amount of drug recovered (μg ± SD)

% of drug recovered

%RSD

0

18

17.7 ± 0.21

98.2

1.17

50

27

29.3 ± 0.3

108.5

1.02

100

36

37.5 ± 0.64

104.3

1.7

150

45

46.6 ± 0.15

103.6

0.32