Skip to main content

Table 4 Temperature effect on ion-isotopic exchange reactions

From: Radio analytical technique in characterization of nuclear grade ion exchangers Duolite ARA-9366B and Purolite NRW-5010

Temperature (°C)

Reaction (1)

Reaction (2)

Duolite ARA-9366B

Purolite NRW-5010

Duolite ARA-9366B

Purolite NRW-5010

Specific reaction rate of rapid process (min−1)

Amount of iodide ion exchanged (mmol)

Initial rate of iodide ion exchange (mmol/min)

Specific reaction rate of rapid process (min−1)

Amount of iodide ion exchanged

(mmol)

Initial rate of iodide ion exchange (mmol/min)

Specific reaction rate of rapid process

(min−1)

Amount of bromide ion exchanged

(mmol)

Initial rate of bromide ion exchange (mmol/min)

Specific reaction rate of rapid process (min−1)

Amount of bromide ion exchanged (mmol)

Initial rate of bromide ion exchange (mmol/min)

30.0

0.201

0.139

0.028

0.246

0.155

0.038

0.165

0.121

0.020

0.203

0.131

0.026

A i = 15,560 cpm

A i = 16,010 cpm

A i = 16,532 cpm

A i = 16,229 cpm

A f = 6,909 cpm

A f = 8,531 cpm

A f = 7,725 cpm

A f = 6,084 cpm

35.0

0.188

0.133

0.025

0.235

0.153

0.036

0.148

0.113

0.017

0.194

0.125

0.024

A i = 15,779 cpm

A i = 15,043 cpm

A i = 15,976 cpm

A i = 16,101 cpm

A f = 5,837 cpm

  

A f = 8,755 cpm

  

A f = 8,050 cpm

 

A f = 7,385 cpm

40.0

0.170

0.129

0.022

0.228

0.150

0.034

0.137

0.106

0.014

0.185

0.120

0.022

A i = 15,834 cpm

A i = 15,756 cpm

A i = 15,473 cpm

A i = 15,998 cpm

A f = 7,664 cpm

A f = 8,912 cpm

A f = 8,319 cpm

A f = 6,302 cpm

45.0

0.156

0.125

0.020

0.219

0.150

0.033

0.125

0.102

0.013

0.178

0.114

0.020

A i = 15,601 cpm

A i = 15,539 cpm

A i = 16,001 cpm

A i = 15,678 cpm

A f = 7,800 cpm

A f = 9,473 cpm

A f = 6,216 cpm

A f = 8,529 cpm

  1. Amount of ion exchange resin = 1.000 g. Concentration of labeled exchangeable ionic solution = 0.001 mol/L. Volume of labeled ionic solution = 250 mL. Amount of exchangeable ions in 250 mL labeled solution = 0.250 mmol.