Table 1 Comparison of the efficiency of some modified electrodes used in the electrocatalysis of methyldopa

From: Application of a modified graphene nanosheet paste electrode for voltammetric determination of methyldopa in urine and pharmaceutical formulation

Electrode

Modifier

Method

pH

Dynamic range (M)

Limit of detection (M)

Reference

Carbon paste

Ferrocene monocarboxylic acid

Voltammetry

7.0

2.0 × 10−7 to 1.0 × 10−4

8.0 × 10−8

Molaakbari et al. ([2014])

Glassy carbon

Pt-Ru nanoparticles

Voltammetry

3.0

5.0 × 10−8 to 4.0 × 10−5

1.0 × 10−8

Shahrokhian and Rastgar ([2011])

Carbon paste

Cellulose acetate/ionic liquids

Voltammetry

5.5

3.48 × 10−5 to 3.7 × 10−4

5.5 × 10−6

Moccelini et al. ([2011])

Carbon nanotube paste

5AEB

Voltammetry

8.0

1.0 × 10−7 to 2.1 × 10−4

4.8 × 10−8

Tajik et al. ([2013a])

Graphene paste

2,7-BF

Voltammetry

7.0

8.0 × 10−8 to 5.0 × 10−4

5.0 × 10−8

This work